1 Quomodo recognoscendas ISO 6162-1 et ISO 6162-2 portum LABIUM?
Vide tabulam 1 et figuram 1, compara clavis dimensiones ad recognoscendas ISO 6162-1 (CODEX SAE J518-1 61) portus vel ISO 6162-2 (CODEX SAE J518-2 62) port.
Mensam 1 Portus dimensiones Flange
Linge magnitudine | Portus dimensiones Flange | ||||||||
ISO 6162-1 (CODEX SAE J518-1 61); | ISO 6162-2 (CODEX SAE J518-2 62); | ||||||||
Metric | Dash | l7 | l10 | d3 | l7 | l10 | d3 | ||
Cochlea metrica | Inch stupra | Cochlea metrica | Inch stupra | ||||||
13 | -8 | 38.1 | 17.5 | M8 | 5/16-18 | 40.5 | 18.2 | M8 | 5/16-18 |
19 | -12 | 47.6 | 22.2 | M10 | 3/8-16 | 50.8 | 23.8 | M10 | 3/8-16 |
25 | -16 | 52.4 | 26.2 | M10 | 3/8-16 | 57.2 | 27.8 | M12 | 7/16-14 |
32 | -20 | 58.7 | 30.2 | M10 | 7/16-14 | 66.7 | 31.8 | M12 | 1/2-13 |
38 | -24 | 69.9 | 35.7 | M12 | 1/2-13 | 79.4 | 36.5 | M16 | 5/8-11 |
51 | -32 | 77.8 | 42.9 | M12 | 1/2-13 | 96.8 | 44.5 | M20 | 3/4-10 |
64 | -40 | 88.9 | 50.8 | M12 | 1/2-13 | 123.8 | 58.7 | M24 | - |
76 | -48 | 106 | 61.9 | M16 | 5/8-11 | 152.4 | 71.4 | M30 | - |
89 | -56 | 121 | 69.9 | M16 | 5/8-11 | - | - | - | - |
102 | -64 | 130 | 77.8 | M16 | 5/8-11 | - | - | - | - |
127 | -80 | 152 | 92.1 | M16 | 5/8-11 | - | - | - | - |
Figura 1 Portus dimensio ad hospites LABIUM
Ex tabula 1, Dash-8 et -12 magnitudinum, eadem est cochleae mensurae ac arcte l7 et l10 pro ISO 6162-1 et ISO 6162-2, diligenter l7 et l10 dimensiones inspicere, ac subtiliter 1 mensurari. mm minusve.
2 Quomodo cognoscendi ISO 6162-1 et ISO 6162-2 fibulae fibulae?
Vide tabulam 2 et figuram 2, figura 3, compara clavis dimensiones ad cognoscendum ISO 6162-1 (CODEX SAE J518-1 61) fibulae flangulae vel ISO 6162-2 (CODEX SAE J518-2 62) fibulae flange.
Fibulae fibulae si finditur, inspicias et dimensiones l7, l12 et d6 conferas.
Si fibulae pars una sit, inspice et l7, l10 et d6 dimensiones compone.
Mensam 2 Fibulae dimensiones Flange
Linge magnitudine | Fibulae dimensiones (mm) | ||||||||
ISO 6162-1 (CODEX SAE J518-1 61); | ISO 6162-2 (CODEX SAE J518-2 62); | ||||||||
Metric | Dash | l7 | l10 | l12 | d6 | l7 | l10 | l12 | d6 |
13 | -8 | 38.1 | 17.5 | 7.9 | 8.9 | 40.5 | 18.2 | 8.1 | 8.9 |
19 | -12 | 47.6 | 22.2 | 10.2 | 10.6 | 50.8 | 23.8 | 10.9 | 10.6 |
25 | -16 | 52.4 | 26.2 | 12.2 | 10.6 | 57.2 | 27.8 | 13.0 | 13.3 b |
32 | -20 | 58.7 | 30.2 | 14.2 | 10.6 a | 66.7 | 31.8 | 15.0 | 13.3 |
38 | -24 | 69.9 | 35.7 | 17.0 | 13.3 | 79.4 | 36.5 | 17.3 | 16.7 |
51 | -32 | 77.8 | 42.9 | 20.6 | 13.5 | 96.8 | 44.5 | 21.3 | 20.6 |
64 | -40 | 88.9 | 50.8 | 24.4 | 13.5 | 123.8 | 58.7 | 28.4 | 25 |
76 | -48 | 106.4 | 61.9 | 30.0 | 16.7 | 152.4 | 71.4 | 34.7 | 31 |
89 | -56 | 120.7 | 69.9 | 34.0 | 16.7 | - | - | - | - |
102 | -64 | 130.2 | 77.8 | 37.8 | 16.7 | - | - | - | - |
127 | -80 | 152.4 | 92.1 | 45.2 | 16.7 | - | - | - | - |
a, 10.6 metricae cochleae et 12.0 pollicis cochleae |
Figure 2 Split LABIUM Fibulae
Figure 3 One-piece LABIUM fibulatis
3 Quomodo cognoscere LABIUM caput
Ex tabula 3 et 4 figura, compara clavis dimensiones ad cognoscendum ISO 6162-1 (CODEX SAE J518-1 61) caput flange vel ISO 6162-2 (CODEX SAE J518-2 62) caput flange.
Et si sulcus identitatis situs in circumferentia orbis disculi, vide figuram 4 caeruleum notatum, est caput flange ISO 6162-2.(Haec nota ad libitum est ante, ergo non omnia capita ISO 6162—2 LABIUM hanc notam habent)
Mensam 3 caput dimensionum Flange
Linge magnitudine | Caput LABIUM dimensiones (mm) | ||||
ISO 6162-1 (CODEX SAE J518-1 61); | ISO 6162-2 (CODEX SAE J518-2 62); | ||||
Metric | Dash | d10 | L14 | d10 | L14 |
13 | -8 | 30.2 | 6.8 | 31.75 | 7.8 |
19 | -12 | 38.1 | 6.8 | 41.3 | 8.8 |
25 | -16 | 44.45 | 8 | 47.65 | 9.5 |
32 | -20 | 50.8 | 8 | 54 | 10.3 |
38 | -24 | 60.35 | 8 | 63.5 | 12.6 |
51 | -32 | 71.4 | 9.6 | 79.4 | 12.6 |
64 | -40 | 84.1 | 9.6 | 107.7 | 20.5 |
76 | -48 | 101.6 | 9.6 | 131.7 | 26 |
89 | -56 | 114.3 | 11.3 | - | - |
102 | -64 | 127 | 11.3 | - | - |
127 | -80 | 152.4 | 11.3 | - | - |
Figura IV Lange caput
Post tempus: Jan-20-2022